Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 12(3): e058605, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35351731

RESUMO

INTRODUCTION: Yaws, caused by the bacterium Treponema pallidum subsp. pertenue, is a neglected tropical disease targeted for eradication by 2030. Improved diagnostics will be essential to meet this goal. Diagnosis of yaws has relied heavily on clinical and serological tools. However, the presence of coendemic cutaneous skin ulcer diseases, such as lesions caused by Haemophilus ducreyi (HD), means these techniques do not provide a reliable diagnosis. Thus, new diagnostic tools are needed. Molecular tools such as PCR are ideal, but often expensive as they require trained technicians and laboratory facilities, which are often not available to national yaws programmes. METHODS AND ANALYSIS: The LAMP4yaws project is a cross-sectional, observational, diagnostic accuracy study of a combined Treponema pallidum (TP) and HD loop mediated isothermal amplification (TPHD-LAMP) test performed under real world conditions in three endemic countries in West Africa. Individuals with serologically confirmed yaws will be recruited in Cameroon, Côte d'Ivoire and Ghana. Each participant will provide paired swabs, one of which will be sent to the respective national reference laboratory for yaws quantitative PCR and the other will be tested for both TP and HD using the TPHD-LAMP test at local district laboratories. Sensitivity and specificity of the TPHD-LAMP test will be calculated against the reference standard qPCR. We will also assess the acceptability, feasibility and cost-effectiveness of the test. We anticipate that results from this study will support the adoption of the TPHD-LAMP test for use in global yaws eradication efforts. ETHICS AND DISSEMINATION: We have received ethical approval from all relevant institutional and national ethical committees. All participants, or their parents or guardians, must provide written informed consent prior to study enrolment. Study results will be published in an open access journal and disseminated with partners and the World Health Organization. TRIAL REGISTRATION NUMBER: NCT04753788.


Assuntos
Haemophilus ducreyi , Úlcera Cutânea , Bouba , Estudos Transversais , Gana , Haemophilus ducreyi/genética , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Estudos Observacionais como Assunto , Reação em Cadeia da Polimerase em Tempo Real , Treponema , Treponema pallidum/genética , Bouba/diagnóstico , Bouba/epidemiologia , Bouba/microbiologia
2.
PLoS Negl Trop Dis ; 15(2): e0009177, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33630852

RESUMO

BACKGROUND: In this work, a platform was developed and tested to allow to detect a variety of candidate viral, bacterial and parasitic pathogens, for acute fever of unknown origin. The platform is based on a centrifugal microfluidic cartridge, the LabDisk ("FeverDisk" for the specific application), which integrates all necessary reagents for sample-to-answer analysis and is processed by a compact, point-of-care compatible device. METHODOLOGY/PRINCIPAL FINDINGS: A sample volume of 200 µL per FeverDisk was used. In situ extraction with pre-stored reagents was achieved by bind-wash-elute chemistry and magnetic particles. Enzymes for the loop-mediated isothermal amplification (LAMP) were pre-stored in lyopellet form providing stability and independence from the cold chain. The total time to result from sample inlet to read out was 2 h. The proof-of-principle was demonstrated in three small-scale feasibility studies: in Dakar, Senegal and Khartoum, Sudan we tested biobanked samples using 29 and 9 disks, respectively; in Reinfeld, Germany we tested spiked samples and analyzed the limit of detection using three bacteria simultaneously spiked in whole blood using 15 disks. Overall during the three studies, the FeverDisk detected dengue virus (different serotypes), chikungunya virus, Plasmodium falciparum, Salmonella enterica Typhi, Salmonella enterica Paratyphi A and Streptococcus pneumoniae. CONCLUSIONS/SIGNIFICANCE: The FeverDisk proved to be universally applicable as it successfully detected all different types of pathogens as single or co-infections, while it also managed to define the serotype of un-serotyped dengue samples. Thirty-eight FeverDisks at the two African sites provided 59 assay results, out of which 51 (86.4%) were confirmed with reference assay results. The results provide a promising outlook for future implementation of the platform in larger prospective clinical studies for defining its clinical sensitivity and specificity. The technology aims to provide multi-target diagnosis of the origins of fever, which will help fight lethal diseases and the incessant rise of antimicrobial resistance.


Assuntos
Febre , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Vírus Chikungunya , DNA Bacteriano , Diagnóstico Diferencial , Alemanha , Humanos , Estudos Prospectivos , Salmonella/genética , Salmonella paratyphi A , Senegal , Sudão
3.
Micromachines (Basel) ; 12(2)2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33562822

RESUMO

This paper presents a universal point-of-care system for fully automated quantification of human T-cell lymphotropic virus type 1 (HTLV-1) proviral load, including genomic RNA, based on digital reverse RNA transcription and c-DNA amplification by MD LAMP (mediator displacement loop-mediated isothermal amplification). A disposable microfluidic LabDisk with pre-stored reagents performs automated nucleic acid extraction, reaction setup, emulsification, reverse transcription, digital DNA amplification, and quantitative fluorogenic endpoint detection with universal reporter molecules. Automated nucleic acid extraction from a suspension of HTLV-1-infected CD4+ T-lymphocytes (MT-2 cells) yielded 8 ± 7 viral nucleic acid copies per MT-2 cell, very similar to the manual reference extraction (7 ± 2 nucleic acid copies). Fully automated sample processing from whole blood spiked with MT-2 cells showed a comparable result of 7 ± 3 copies per MT-2 cell after a run time of two hours and 10 min.

4.
Anal Chem ; 93(5): 2854-2860, 2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33481582

RESUMO

We implement dual-volume centrifugal step emulsification on a single chip to extend the dynamic range of digital assays. Compared to published single-volume approaches, the range between the lower detection limit (LDL) and the upper limit of quantification (ULQ) increases by two orders of magnitude. In comparison to existing multivolume approaches, the dual-volume centrifugal step emulsification requires neither complex manufacturing nor specialized equipment. Sample metering into two subvolumes, droplet generation, and alignment of the droplets in two separate monolayers are performed automatically by microfluidic design. Digital quantification is demonstrated by exemplary droplet digital loop-mediated isothermal amplification (ddLAMP). Within 5 min, the reaction mix is split into subvolumes of 10.5 and 2.5 µL, and 2,5k and 176k droplets are generated with diameters of 31.6 ± 1.4 and 213.9 ± 7.5 µm, respectively. After 30 min of incubation, quantification over 5 log steps is demonstrated with a linearity of R2 ≥ 0.992.

5.
Methods Mol Biol ; 2142: 147-164, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32367366

RESUMO

Two one-step real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of Zika virus (ZIKV) were developed, based on two different primer design approaches: (1) open source, based on a combination of sequence diversity clustering (phylogeny and principal component analysis) and LAVA algorithm, using 45 whole genome ZIKV sequences retrieved from the National Center for Biotechnology Information (NCBI) database; (2) standard software for LAMP primer design (Primer Explorer V4), using 59 sequences of the ZIKV 3' UTR. The assays were firstly evaluated with External Quality Assessment panels from INSTAND e.V. (Germany) and EVD-LabNet (The Netherlands) including 4 and 12 unknown samples, respectively, and secondly, with 9 human, mosquito, and monkey ZIKV isolates from Africa (Senegal, Ivory Coast, and Uganda) and America (Brazil). The limit of detection as determined by probit analysis was 181 molecules for both RT-LAMP assays, and 100% reproducibility in the assays was obtained for 103 molecules (4/8 repetitions were positive for 102 molecules). Both assays were specific, amplifying only ZIKV RNA and not cross-detecting other arboviruses included in this study.


Assuntos
Algoritmos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Software , Infecção por Zika virus/diagnóstico , Zika virus/genética , África , Animais , Brasil , Células Cultivadas , Culicidae/virologia , Alemanha , Haplorrinos , Humanos , Ensaio de Proficiência Laboratorial , Limite de Detecção , Técnicas de Diagnóstico Molecular/normas , Países Baixos , Técnicas de Amplificação de Ácido Nucleico/normas , RNA Viral/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Zika virus/isolamento & purificação , Infecção por Zika virus/veterinária
6.
Emerg Infect Dis ; 26(2): 282-288, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31961303

RESUMO

Yaws, a neglected tropical disease caused by the bacterium Treponema pallidum subspecies pertenue, manifests as ulcerative skin lesions. Nucleic acid amplification tests, like loop-mediated isothermal amplification (LAMP), are versatile tools to distinguish yaws from infections that cause similar skin lesions, primarily Haemophilus ducreyi. We developed a novel molecular test to simultaneously detect T. pallidum and H. ducreyi based on mediator displacement LAMP. We validated the T. pallidum and H. ducreyi LAMP (TPHD-LAMP) by testing 293 clinical samples from patients with yaws-like lesions. Compared with quantitative PCR, the TPHD-LAMP demonstrated high sensitivity and specificity for T. pallidum (84.7% sensitivity, 95.7% specificity) and H. ducreyi (91.6% sensitivity, 84.8% specificity). This novel assay provided rapid molecular confirmation of T. pallidum and H. ducreyi DNA and might be suitable for use at the point of care. TPHD-LAMP could support yaws eradication by improving access to molecular diagnostic tests at the district hospital level.


Assuntos
Cancroide/diagnóstico , Haemophilus ducreyi/isolamento & purificação , Treponema pallidum/isolamento & purificação , Bouba/diagnóstico , Cancroide/microbiologia , Criança , Feminino , Gana , Humanos , Masculino , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Papua Nova Guiné , Sensibilidade e Especificidade , Bouba/microbiologia
7.
PLoS Negl Trop Dis ; 12(5): e0006381, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29813062

RESUMO

BACKGROUND: 4 one-step, real-time, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed for the detection of dengue virus (DENV) serotypes by considering 2,056 full genome DENV sequences. DENV1 and DENV2 RT-LAMP assays were validated with 31 blood and 11 serum samples from Tanzania, Senegal, Sudan and Mauritania. DENV3 and DENV4 RT-LAMP assays were validated with 25 serum samples from Cambodia. METHODOLOGY/PRINCIPAL FINDINGS: 4 final reaction primer mixes were obtained by using a combination of Principal Component Analysis of the full DENV genome sequences, and LAMP primer design based on sequence alignments using the LAVA software. These mixes contained 14 (DENV1), 12 (DENV2), 8 (DENV3) and 3 (DENV4) LAMP primer sets. The assays were evaluated with an External Quality Assessment panel from Quality Control for Molecular Diagnostics. The assays were serotype-specific and did not cross-detect with other flaviviruses. The limits of detection, with 95% probability, were 22 (DENV1), 542 (DENV2), 197 (DENV3) and 641 (DENV4) RNA molecules, and 100% reproducibility in the assays was obtained with up to 102 (DENV1) and 103 RNA molecules (DENV2, DENV3 and DENV4). Validation of the DENV2 assay with blood samples from Tanzania resulted in 23 samples detected by RT-LAMP, demonstrating that the assay is 100% specific and 95.8% sensitive (positive predictive value of 100% and a negative predictive value of 85.7%). All serum samples from Senegal, Sudan and Mauritania were detected and 3 untyped as DENV1. The sensitivity of RT-LAMP for DENV4 samples from Cambodia did not quite match qRT-PCR. CONCLUSIONS/SIGNIFICANCE: We have shown a novel approach to design LAMP primers that makes use of fast growing sequence databases. The DENV1 and DENV2 assays were validated with viral RNA extracted clinical samples, showing very good performance parameters.


Assuntos
Vírus da Dengue/genética , Vírus da Dengue/isolamento & purificação , Dengue/virologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Primers do DNA/genética , Vírus da Dengue/classificação , Vírus da Dengue/metabolismo , Humanos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Filogenia , RNA Viral/genética , Transcrição Reversa , Tanzânia
8.
PLoS Negl Trop Dis ; 12(5): e0006448, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29813065

RESUMO

BACKGROUND: A single-tube one-step real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid detection of chikungunya virus (CHIKV) targeting the conserved 6K-E1 target region was developed. The assay was validated with sera collected from a CHIKV outbreak in Senegal in 2015. METHODOLOGY/PRINCIPAL FINDINGS: A novel design approach by combining Principal Component Analysis and phylogenetic analysis of 110 available CHIKV sequences and the LAMP oligonucleotide design software LAVA was used. The assay was evaluated with an External Quality Assessment panel from the European Network for Diagnostics of "Imported" Viral Diseases and was shown to be sensitive and specific and did not cross-detect other arboviruses. The limit of detection as determined by probit analysis, was 163 molecules, and 100% reproducibility in the assays was obtained for 103 molecules (7/8 repetitions were positive for 102 molecules). The assay was validated using 35 RNA samples extracted from sera, and results were compared with those obtained by quantitative RT-PCR carried out at the Institut Pasteur Dakar, demonstrating that the RT-LAMP is 100% sensitive and 80% specific, with a positive predictive value of 97% and negative predictive value of 100%. CONCLUSIONS/SIGNIFICANCE: The RT-LAMP appeared to show superior performance with material stored for months compared to qRT-PCR and can be therefore recommended for use in infrastructures with poor settings.


Assuntos
Febre de Chikungunya/virologia , Vírus Chikungunya/isolamento & purificação , Genoma Viral , Técnicas de Amplificação de Ácido Nucleico/métodos , Febre de Chikungunya/diagnóstico , Vírus Chikungunya/classificação , Vírus Chikungunya/genética , Primers do DNA/genética , Humanos , Filogenia , Sensibilidade e Especificidade
9.
PLoS Negl Trop Dis ; 12(4): e0006396, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29649256

RESUMO

We show proof of concept for gene targets (polA, tprL, and TP_0619) that can be used in loop-mediated isothermal amplification (LAMP) assays to rapidly differentiate infection with any of the three Treponema pallidum subspecies (pallidum (TPA), pertenue (TPE), and endemicum (TEN)) and which are known to infect humans and nonhuman primates (NHPs). Four TPA, six human, and two NHP TPE strains, as well as two human TEN strains were used to establish and validate the LAMP assays. All three LAMP assays were highly specific for the target DNA. Amplification was rapid (5-15 min) and within a range of 10E+6 to 10E+2 of target DNA molecules. Performance in NHP clinical samples was similar to the one seen in human TPE strains. The newly designed LAMP assays provide proof of concept for a diagnostic tool that enhances yaws clinical diagnosis. It is highly specific for the target DNA and does not require expensive laboratory equipment. Test results can potentially be interpreted with the naked eye, which makes it suitable for the use in remote clinical settings.


Assuntos
Técnicas de Amplificação de Ácido Nucleico/métodos , Treponema pallidum/isolamento & purificação , Bouba/microbiologia , Proteínas de Bactérias/genética , Técnicas de Tipagem Bacteriana , DNA Bacteriano/genética , Humanos , Filogenia , Treponema pallidum/classificação , Treponema pallidum/genética
10.
Anal Chem ; 90(7): 4741-4748, 2018 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-29508609

RESUMO

A variety of real-time detection techniques for loop-mediated isothermal amplification (LAMP) based on the change in fluorescence intensity during DNA amplification enable simultaneous detection of multiple targets. However, these techniques depend on fluorogenic probes containing target-specific sequences. That complicates the adaption to different targets leading to time-consuming assay optimization. Here, we present the first universal real-time detection technique for multiplex LAMP. The novel approach allows simple assay design and is easy to implement for various targets. The innovation features a mediator displacement probe and a universal reporter. During amplification of target DNA the mediator is displaced from the mediator displacement probe. Then it hybridizes to the reporter generating a fluorescence signal. The novel mediator displacement (MD) detection was validated against state-of-the-art molecular beacon (MB) detection by means of a HIV-1 RT-LAMP: MD surpassed MB detection by accelerated probe design (MD: 10 min, MB: 3-4 h), shorter times to positive (MD 4.1 ± 0.1 min shorter than MB, n = 36), improved signal-to-noise fluorescence ratio (MD: 5.9 ± 0.4, MB: 2.7 ± 0.4; n = 15), and showed equally good or better analytical performance parameters. The usability of one universal mediator-reporter set in different multiplex assays was successfully demonstrated for a biplex RT-LAMP of HIV-1 and HTLV-1 and a biplex LAMP of Haemophilus ducreyi and Treponema pallidum, both showing good correlation between target concentration and time to positive. Due to its simple implementation it is suggested to extend the use of the universal mediator-reporter sets to the detection of various other diagnostic panels.

11.
PLoS One ; 10(11): e0143100, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26588087

RESUMO

The bacterium Treponema pallidum is known to cause syphilis (ssp. pallidum), yaws (ssp. pertenue), and endemic syphilis (ssp. endemicum) in humans. Nonhuman primates have also been reported to be infected with the bacterium with equally versatile clinical manifestations, from severe skin ulcerations to asymptomatic. At present all simian strains are closely related to human yaws-causing strains, an important consideration for yaws eradication. We tested clinically healthy Guinea baboons (Papio papio) at Parc National Niokolo Koba in south eastern Senegal for the presence of anti-T. pallidum antibodies. Since T. pallidum infection in this species was identified 50 years ago, and there has been no attempt to treat non-human primates for infection, it was hypothesized that a large number of West African baboons are still infected with simian strains of the yaws-bacterium. All animals were without clinical signs of treponematoses, but 18 of 20 (90%) baboons tested positive for antibodies against T. pallidum based on treponemal tests. Yet, Guinea baboons seem to develop no clinical symptoms, though it must be assumed that infection is chronic or comparable to the latent stage in human yaws infection. The non-active character is supported by the low anti-T. pallidum serum titers in Guinea baboons (median = 1:2,560) versus serum titers that are found in genital-ulcerated olive baboons with active infection in Tanzania (range of medians among the groups of initial, moderate, and severe infected animals = 1:15,360 to 1:2.097e+7). Our findings provide evidence for simian infection with T. pallidum in wild Senegalese baboons. Potentially, Guinea baboons in West Africa serve as a natural reservoir for human infection, as the West African simian strain has been shown to cause sustainable yaws infection when inoculated into humans. The present study pinpoints an area where further research is needed to support the currently on-going second WHO led yaws eradication campaign with its goal to eradicate yaws by 2020.


Assuntos
Anticorpos/sangue , Papio papio/sangue , Sífilis/sangue , Treponema pallidum/patogenicidade , Animais , Anticorpos/imunologia , Humanos , Papio papio/microbiologia , Senegal , Úlcera Cutânea/sangue , Úlcera Cutânea/imunologia , Úlcera Cutânea/patologia , Sífilis/microbiologia , Sífilis/transmissão , Tanzânia , Treponema pallidum/imunologia
12.
PLoS Negl Trop Dis ; 9(3): e0003637, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25803295

RESUMO

There is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue) may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO) recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes. It was hypothesized that commercially available serological tests detect simian anti-T. pallidum antibody in serum samples of baboons, with comparable sensitivity and specificity to their results on human sera. Test performances of five different treponemal tests (TTs) and two non-treponemal tests (NTTs) were evaluated using serum samples of 57 naturally T. pallidum-infected olive baboons (Papio anubis) from Lake Manyara National Park in Tanzania. The T. pallidum particle agglutination assay (TP-PA) was used as a gold standard for comparison. In addition, the overall infection status of the animals was used to further validate test performances. For most accurate results, only samples that originated from baboons of known infection status, as verified in a previous study by clinical inspection, PCR and immunohistochemistry, were included. All tests, TTs and NTTs, used in this study were able to reliably detect antibodies against T. pallidum in serum samples of infected baboons. The sensitivity of TTs ranged from 97.7-100%, while specificity was between 88.0-100.0%. The two NTTs detected anti-lipoidal antibodies in serum samples of infected baboons with a sensitivity of 83.3% whereas specificity was 100%. For screening purposes, the TT Espline TP provided the highest sensitivity and specificity and at the same time provided the most suitable format for use in the field. The enzyme immune assay Mastblot TP (IgG), however, could be considered as a confirmatory test.


Assuntos
Doenças dos Macacos/epidemiologia , Doenças dos Macacos/microbiologia , Papio , Testes Sorológicos/veterinária , Treponema pallidum/imunologia , Bouba/veterinária , Testes de Aglutinação/veterinária , Animais , Anticorpos Antibacterianos/sangue , Doenças dos Macacos/imunologia , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Tanzânia/epidemiologia , Bouba/epidemiologia , Bouba/microbiologia
13.
J Vet Diagn Invest ; 22(1): 61-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20093684

RESUMO

Real-time reverse transcription loop-mediated isothermal amplification (real-time RT-LAMP) holds substantial potential as a highly sensitive, specific, and easy-to-perform molecular technique for pathogen detection in clinical samples. In the current study, the analytical and diagnostic performance of 2 commercial real-time RT-LAMP kits, Avian Flu H5 and Avian Flu H7, in detecting Avian influenza virus (AIV) infections were evaluated and compared with validated real-time reverse transcription polymerase chain reaction (RT-PCR) assays using RNA from reference virus isolates of subtypes H5 (n = 24) and H7 (n = 25) and of phylogenetically related subtypes (n = 20). When real-time RT-LAMP was carried out according to the recommendations of the manufacturer, 3 out of 24 H5 isolates and 8 out of 25 H7 reference strains were not detected. Prolonging the amplification phase resulted in detection of all H5 isolates but also in false positive detection of 2 non-H5 isolates. Real-time RT-LAMP specific to H7 failed to detect 2 H7 isolates after prolonged amplification. According to the examination of RNA log dilutions, the sensitivity of the real-time RT-LAMP assays, for a number of historic but also recent strains, was considerably lower compared with subtype-specific real-time RT-PCR assays. Application of the real-time RT-LAMP assays for analysis of diagnostic samples from wild birds confirmed their lower sensitivity. Commercial real-time RT-LAMP as tested in this study with a broad range of AIV H5 and H7 strains of phylogenetically diverse yet recent origin, holds some promise for routine veterinary diagnostic purposes, although real-time RT-LAMP was markedly more vulnerable to a reduction of detection limits because of strain-specific sequence variation than subtype-specific real-time RT-PCR.


Assuntos
Glicoproteínas de Hemaglutininação de Vírus da Influenza/genética , Vírus da Influenza A/genética , Influenza Aviária/virologia , Técnicas de Amplificação de Ácido Nucleico/veterinária , Animais , Aves , Glicoproteínas de Hemaglutininação de Vírus da Influenza/isolamento & purificação , Vírus da Influenza A/classificação , Vírus da Influenza A/metabolismo , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...